Lead-free terminations, RoHS and Reach Compliant
Features
Capacitance ranging from 0.1μF to 600μF
Voltage rating of 6V - 50V
Size A, B, C, G, D
Ordering Information
CT45 |
-G |
-X5R |
-50V |
226 |
-M |
-T |
Series |
Case size |
Dielectric |
Rated voltage |
Capacitance |
Capacitance tolerance |
Packaging |
CT45 |
A B C G D |
X5R |
6V 0V 16V 25V 35V 50V |
First two digits represent significant figures. Third digit specifies number of zeros. Example: 106=10000000pF =10μF |
K=±10% M=±20% |
T=Bulk E=7” Reel |
Dimensions
|
|
|
|
|
Unit:mm |
|||
Size Code |
L±0.20 |
W |
+0.20 -0.10 |
H |
+0.30 -0.10 |
W1±0.20 |
A |
+0.30 -0.30 |
A |
3.20 |
1.60 |
1.60 |
1.20 |
0.80 |
|||
B |
3.50 |
2.80 |
1.90 |
2.20 |
0.80 |
|||
C |
6.00 |
3.20 |
2.60 |
2.20 |
1.30 |
|||
G |
5.30 |
4.00 |
6.90 |
2.40 |
1.40 |
|||
D |
7.30 |
4.30 |
2.90 |
2.40 |
1.30 |
|||
Electrical Characteristics
Item |
Specification Limits |
Measuring Conditions |
|
Operating Temperature Range |
X7R |
-55℃ to +125℃ |
— |
X5R |
-55℃ to +85℃ |
||
Capacitance |
Within specified tolerance |
— |
|
Dissipation Factor |
X7R |
UR≤50V , tgδ≤3.5%; 50V<UR≤500V , tgδ≤2.5%; |
CR≤10μF 1kHz±10% 1V±0.2V CR>10μF 120Hz±10% 0.5V±0.2V |
X5R |
UR≤50V, tgδ≤10%; 50V<UR≤100V , tgδ≤3.5%; 100V<UR≤500V , tgδ≤2.5%; |
||
Insulation Resistance |
4000MΩ or 100MΩ·μF whichever is less |
Rated voltage shall be applied for 2 minutes, charge and discharge current shall be limited to 50mA (max). |
|
Dielectric Strength |
No breakdown or visual defects |
Rated voltage shall be applied within following conditions for 5 seconds: UR<500V 2.5UR UR=500V 1.5UR Charging and discharging current shall be 50mA or less. |
|
Temperature Characteristics |
±15% |
Capacitance change with reference to +25℃ |
Storage
To maintain the solderability of terminal electrodes and to keep packaging materials in good condition, measures should be taken to control temperature and humidity.
Recommended conditions:
l Temperature: Below 40℃
l Humidity: Below 70% RH
Even under ideal storage conditions, solderability of capacitors is deteriorated as time passes, so capacitors shall be used within 12 months from the time of delivery. When exceeding the above period, please check solderability before applying the capacitors to your circuit.
Applications